This blog focuses on industrial, inline process refractometers and their use in industrial applications. Refractometry is used to measure the refractive index of a substance in order to determine its composition or purity. Posts include information on theory, construction, installation, new products and new markets.
Electron Machine Corporation | Umatilla, FL | PHONE: 352-669-3101 | ElectronMachine.com
The Electron Machine Support Team is Here for You!
If you have questions about Electron Machine products, or need any type of assistance, our experienced support team is here to help. Call us at +1 352-669-3101 or send an email to sales@electronmachine.com.
From all of us at Electron Machine, we thank you for your business and look forward to serving you in the future.
Our goal is to provide you with the highest level of customer service possible.
Hydrochloric Acid Concentration Control Using Inline Process Refractometers
Measuring the Concentration of Hydrochloric Acid (sometimes referred to as Concentration Density of Hydrochloric Acid) is a critical part of the production process for all applications mentioned above. It is important to closely monitor the concentration levels of the hydrochloric acid with a high degree of accuracy and reliability. Although Hydrochloric Acid Concentration can be created in excess of 40% (Concentrated Grade), Industrial Grade high concentration HCL is 30-35%, which is most stable for transport and storage, and reduces the loss of HCL to evaporation. As the concentration lowers, other names for the concentrations exist, such as Muriatic Acid which can range in concentrations of 21-35%.
Hydrochloric Acid is a prime candidate for concentration measurement through use of its Refractive Index (R.I.). Unlike Sulfuric Acid, the R.I. for HCL Acid is extremely linear, rising from 0% at 1.333 R.I. to 40% at 1.425 R.I.
An inline process refractometer is used to monitor the concentration of Hydrochloric Acid level in real time. Based upon the refractive index (R.I.) of a given aqueous solution, the refractometer can determine the HCL concentration of the solution and relay that value in real time for proactive process control.
The Electron Machine Corporation’s family of inline process refractometers are the ideal instrument for measuring these concentrations.
Electron Machine Corporation manufactures the MPR E-Scan; a rugged, dependable, accurate, and cost effective in-line refractometer. Capabilities include 4-20mA and 0-10VDC outputs, a variety of up to 8 internal relays for direct control of a variety of valves, alarms, and warning indicators, as well as the capability of saving up to 99 different recipes each with their own alarms, set-points and controls. The wetted metal of the sensing head is normally made from Tantalum (other alloys are available). The non-wetted parts and the interconnection cable can be Teflon® coated for added protection.
Benefits of Using the MPR E-Scan:
- High precision and durability in extremely corrosive conditions.
- Continuous quality control.
- Hazardous chemical environmental and safety regulation compliance.
- Low maintenance, repeatable operation.
Please contact Electron Machine Corporation (+1 352-669-3101) for more information or check out our many accounts on social media.
Inline Process Refractometers Used in Vaccine and Drug Development
Inline Process Refractometers for the Pharmaceutical and Food Processing Industries
When it comes to easily, reliably and accurately determining the concentration, identification or purity of substances, refractometry is the ideal method. Inline process refractometers are especially helpful as they supplement laboratory research and contribute to production improvement. These process analyzers deliver results within fractions of a second, allowing real-time monitoring and automatic control of processes.
Electron Machine Corporation's MPR E-Scan™ inline refractometers provide process analysis and control of liquid and slurry process streams in pharmaceutical and food processing applications. The MPR E-Scan™ provides accurate control and precise monitoring of variables in process streams, including percent concentration, solids dissolution, and solution reduction. The inline process refractometer also excels in measuring and managing crystallization, verifying and regulating the correct mix of various compounds, and determining the sugar concentration in a wide variety of products. In addition, the MPR E-Scan™ is often used to track concentrations in evaporation processes.
The MPR E-Scan™ is available in a broad range of models to accomodate a wide variety of measurement ranges and resolutions, providing users an abundance of choices to fit the right equipment to the right application.
Designed with ruggedness and durability in mind, the IP65 / NEMA 4X rated MPR E-Scan™ will withstand the rigors of CIP (Clean-in-Place), allowing the inline process refractometer to be thoroughly and meticulously cleaned at any time in a process environment. Each process refractometer is designed and manufactured specifically for each application, assuring trouble-free service with a minimum amount of maintenance for years to come.
The operation of the MPR E-Scan™ inline process refractometer is based upon the principle of light reflection. Light radiated from the LED passes through the prism surface to be reflected from a mirror to the prism-to-process interface. The light reaching this interface intersects the same interface over a series of angles chosen to include critical angle for the process being measured. Light intersecting the interface at an angle greater than critical angle is refracted into the solution. Light intersecting the interface at less than critical angle is reflected up to a second mirror and out of the prism up to the CCD linear array to be scanned.
In short, the MPR E-Scan™ inline process refractometer makes process metrics more visible to the user and significantly reduces product quality fluctuations. This increases efficiency, lowers production costs, and increases process reliability. The MPR E-Scan™ can be applied to a wide range of applications in the pharmaceutical and food industries, thanks to their field-proven and reliable technology.
Electron Machine Corporation
https://electronmachine.com
352-669-3101
New! 24 Volt, DC-DC Option for the DCR E-Scan and MPR E-Scan In-line Process Refractometers
“This is the successful culmination of many hours work and several revisions,” says Jack Wilburn, Operations Manager for Electron Machine, “and provides us the ability to satisfy the needs of many clients who seek a mobile solution for in-line process measurement of Refractive Index.”
Reading Milk Fat content, de-icing solutions, and the measurement of sugars on harvesting equipment are just a few of the applications this new power supply address. Static operations that benefit from this advancement are solar operated locations as well as areas that lack high voltage AC service. This new option provides a solution for these low power areas.
Read the full article here.
Please contact Electron Machine Corporation (+1 352-669-3101) for more information, or check out our accounts on most all social media platforms.